Are you sure it is the pump running and not the blower for the heat exchanger? Great hardware, awful software. Press J to jump to the feed. We might be able to do something about it. How does Navien intelligent recirculation work? Designed for recirculation of domestic hot water in applications where a dedicated return line is not available. This week we added the NaviLink to our unit (NPE-240A2). I even tried using a ethernet hard wire to my router and it still did not connect. I have had the system for a number of months now and overall I really like it. Ive installed hundreds of them. PFFW-001, NaviCirc Kit: 30022965A. It will reduce the energy consumption and deliver you the best heating efficiency. Navien CR-240a tankless water heater issues - DIY Home Improvement Forum Nearly Instantaneous hot water can be achieved with a Navien tankless water heaters with a proper recirculation system but is dependant on the homes piping system.Please contact Harry Eklof \u0026 Associates for more information or to set up a training class for your company. is this recirculation pump just recently installed? I just had a Navien 210A installed at my house. I too have the NPE-240A, and this is what was explained to me. Read the user's Navien nr-240a manual to get information on how to flush the heat exchanger and how to reset remote for Navien tankless water heater. Eric Alvarez is an HVAC guy based in El Paso, Texas, United States. Can anyone clarify? Learn more about our products for home owners. I set my first three dip switch settings to ON, ON, OFF which is what the manual said the settings are supposed to be for intelligent pre-heating. It is assumed that when you connect a hot button that you only want it to recirculate when you hit the button, and it is assumed that when you connect a Navilink that you will set up a schedule and have it recirculate within those hours specified. My unit is a replacement for an existing electric tank recirc loop system. You can find one on the PCB and the other one on the front panel. Deactivate Circulator Timer and Periods. While the line might still be hot, it wont stay that way with cold water being pumped in. Create an account to follow your favorite communities and start taking part in conversations. Read the user's Navien nr-240a manual to get information on how to flush the heat exchanger and reset the remote for Navien tankless water heater. PFFW-001, NaviCirc Kit: 30022965A. Position the 2-way valve inside the water heater to EXT. I'll have to look at the manual again, but the one I have does detail dip switch settings. For a better experience, please enable JavaScript in your browser before proceeding. Once you turn that DIP switch, the water heater software will monitor the flow demands over a 7 day cycle and recirculate the water from the following week based on water usage. 22 Installing the Water Heater CAUTION Do not remove recirculation cap Internal Recirculation Mode The following diagram shows the internal . It will leave the valves open but the internal pump will never turn on. It looks like you're using an ad blocker. Basically, you add a host to a vCenter cluster, NSX-T bits should start to automatically installing on new host. I don't have any answers to your questions, but I am curious to know how you like the overall setup? They stated that the "Default" re-circulation schedule is every 30 minutes if it senses a 9 degree drop. How To Use Recirculation Mode On Navien Water Heater? I had a dedicated external recirculation line installed to use with the Navien internal pump. Navien tankless water heater recirculation | 2016-04-01 | Plumbing and Navien OEM Parts So I purchased a NR-20DU remote controller to gain the programmable recirculation feature. My water is well water so I am assuming this is correct. . PreReqs: Homebrew Installing OpenConnect: Launch MacOS Terminal brew install openconnect Getting VPN IP's/DNS Endpoints from AnyConnect: The information is typically located in your profile xml files located here: /opt/cisco/anyconnect/profile/somethingsomething.xml In the xml file, you are looking for "typicallyaDNSName.com" entry. Efficient and earth-friendly products designed for any size home. The recirculation system needs a line running back to the water heater from the farthest faucet . The manual also has dip switch settings for "External Recirculation" but I am afraid if I set it to that setting it will not use the "intelligent computer" and run all the time. Solution: Get in touch with Navien technical support or a professional heater repairman. * Existing installations may require the purchase of a new main PCB and front control panel. If any particular ad is your REASON for blocking ads, please let us know. Hi therejust curious since I was considering a Navien 240A. I have even turned off the scheduling function cause it's wasteful if I'm not around and forget to turn it off. Sorry just saw this. JavaScript is disabled. We seem to have to run hot water for a long time to get it hot. It allows you to choose the time in 30 minutes intervals. If thats correct, then yes I do want to set it to External, and flip the valve. Do not advertise or try to compare pricing. Navien Recirculation Settings: Everything You Need To Know. Hope this helps. ktpass /pass ReallySecurePas5word /ptype K, The VPN client was unable to successfully verify the IP forwarding table modification. To make sure that the model has this feature, you simply need to check to see if there is an 'A' at the end of the model number. Once you connect a hot button or a Navilink to the water heater, this overrides the default every 30 minutes scheduleperiod. Finally I got them to call the Navien support line to set them straight. NPE-240A Downloads Download the new Navien mobile app! It is not in the manual. In reading the comments there seems to be confusing information as to whether the schedule button should be set to ENABLE or DISABLE. Also, NaviLink Lite does not require external power. I've also updated the blog post w/ summarized information from everyone's comments. Thanks for any insight you can provide. Your observation about the Enable/Disable selection saved the day! Thank you for posting. This seems relatively new for Navien and is in a recent Navien technical bulletin from 04/18/16. Default recirculation schedule is every 30 minutes if a 9F degree drop is sensed. Navien Manuals Water Heater NPE-180A Service manual Navien NPE-180A Service Manual Npe series condensing water heaters Also See for NPE-180A: User manual , Installation manual (71 pages) , Operation manual (20 pages) 1 2 3 4 Table Of Contents 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 From what I have read, I need to set SW1 to on to enable the internal loop recirculation. external recirculation pump. Thanks. External recirc pump and check valves not included. Can you Ask an Expert Home Improvement Questions HVAC Questions Michael Ferryman 1,933 Satisfied Customers Operating Engineer at NRG Energy Michael Ferryman is online now Related HVAC Questions I don't know the best place to post this, but i happened to be fiddling around in the NaviLink app on Feb. 1 and it asked to update. Parameter access and and parameters are listed here in section 6.5 page 65. Thanks in advance for your time. http://us.navien.com/Engineers_Features_Benefits/ComfortFlow_Technology/. It just will not connect. Building penetrations are reduced with Navien's common venting feature. It looks like you're using an ad blocker. What I am going to discuss in this article is-. JavaScript is disabled. PDF Navien npe-240a recirculation settings - Ziepniekkalns Dave, if you could enlighten me (other users) on what you had to do to get scheduling to work that would be great. 6. Navien NPE-240A Installation Manual Page: 27 - mans.io By using a kerberos keytag, I'm able to in the very least obfuscate the username and password into a file for upload into the iDRAC. 1. The A2 is the upgrade that started shipping in March 2021. Then if that doesn't work, I would keep it at 1 minute, and then set 14 to 1 minute, and I would also try 14 at its max. If you'd like to support the site, please allow ads. Navien ComfortFlow Technology Explained - Seekyt (Internal Recirculation would be the opposite), Parameter 18 set to On (This is to enable. Zsoldier, he dip switches there dont get into the real detail of the programming. Navien NP-240A Manuals | ManualsLib Set the position of the 2-way valve, which you can find inside the water heater. We do not have a hot button. NPE-A2 Series | Navien A tankless water heater, whether it comes from Navien or other brands, will provide you a reliable service for up to 20 years if you maintain it according to the manual. This gives users hot water when they need it, saving water and money. Thanks for the summary and the reply to my question as well as the others. Years of experience in the HVAC field have taught him many lessons, not the least of which is that the value of quality and knowledge far exceeds any promised initial savings. Condensing combi-boilers deliver high-efficiency endless hot water and space heating in one compact unit. Navien 240a external recirculation settings with thermal comfort valve I am looking at options for my recirculation too. 7. This was on 4.6.x. As for parameters 12 & 14, I would at least try to play with them to see if it helps. If you'd like to support the site, please allow ads. Protect your water supply and your water heating equipment with eco-friendly water treatment solutions. Research I've seen suggests this will save over 90% of the energy costs associated with 24 hour recirculation, which is essentially what you have. The Problem is the damn Navilink and the support they have from Korea. It gives me the option to 'control' and create a weekly schedule. We are on well water and have a low flowing well. These are your VPN endpoints that you would need to pass to openconnect. Space-saving high-efficiency condensing boilers provide the ultimate heating and comfort experience. Can anyone lend some guidance as to what the recommended dip switch setting should be? I also bought a Navicirc. I simply cannot believe the iPhone app won't allow both recirc schedule on a dedicated loop and ability to turn on/off recirc at other times. You are right. Specifically, you can find a number of dip switches on these two locations. *DIP Switches need to be set properly as well. Also the unit needs to be set to utilize the recirculation feature. I hate the app as it is just not user friendly. So you could restart the cm-inventory service till you are blue in the face and get nowhere be. When in a schedule the unit will circulate and heat according to the parameter settings. Note: You can use the Internal Recirculation Mode in the A2 models only. I had a dedicated external recirculation line installed to use with the Navien internal pump. Navien 240A Recirculation Settings You are using an out of date browser. Press question mark to learn the rest of the keyboard shortcuts. On-demand takes a bit longer to heat up, but oh well. Apple iOS Google Android NPE-240A Downloads Click here to see downloads for other products. Assuming you've created a Transport Node Profile and associated w/ the cluster. Say with external pump being used function, if your recirculation line connects together outside of the heater like with an actual return line then set it external. Navien Npe 240A Recirculation Settings Typically with tankless water heaters, the circulator needs to be properly sized. Given the highly critical reviews of the NaviLink app on the Apple iOS App Store, I am reluctant to buy until I can verify that 1) re-enabling schedules using the NaviLink app is easy to do and 2) we can use the NaviLink app to activate the CP on-demand (in other words, the app does, indeed, have a software-based button). Using the internal pump to set up an external re circulation line through the cold water system as return with a Grundfos comfort valve at the last fixture in the line. Internal Recirculation and make the selection by pressing the Ok button. Recirculation is basically just keeping the hot water in the plumbing hot so you get hot water faster. Even if the primary node associated w/ the VIP, if configured, is not necessarily in charge of inventory. The house is set up with recirculation, though I am not sure where in the house the "T" on the system is located. DIP Switch 1 Off, 2 On. Navien Now Doing Business in Canada as Navien Canada, Inc. Navien Begins Shipping PeakFlowC Commercial Scale Prevention Systems. A VPN connection will not be established. I was reading the directions, and it wants me to set the Heater to External recirculation. This appears to affect NSX-T 2.5 and 2.5.1. 21. Attach the water supply to support recirculation. With the -A uinits (with the recirculation pump) does that pump have to run to supply on demand hot water? Internal with internal pump. I, recently had a Navien NPE-240A unit installed. If any particular ad is your REASON for blocking ads, please let us know. Learn more about our products for home owners. Factory Setting of DIP Switch. The H2Air Kit utilizes the NPE-A2 pump to circulate the hot water for the hydronic air handler. New Problem - I cannot connect my NaviLink to my home wifi. Navien Recirculation Settings: Everything You Should Know Now with a single NPE240A and the re circulation I can keep hot water to the last fixture in the home. My NaviLink was working just fine for about2 months. This chapter will walk you through the step-by-step guide to let you learn how to use the recirculation mode. Note: You must set up the Time Settings in the Configuration menu to choose these options. Connect the External Pump Wire to the proper wires from the. I just want to make sure my understanding is correct. Also I set dip switch 5 to "ON" for the well pump setting. At the push of a button, Navien's HotButton accessory activates the internal recirculation pump and gas-fired burner to heat up the water in the supply lines. Hello, You might want to talk with the folks at ACT, 714-668-1200 www.gothotwater.com. High-efficiency condensing and non-condensing tankless water heaters offer endless hot water and reduce gas usage. Simply visit your local Navien wholesaler and pick up everything you need. Enable=Enabled, and Disable=Disabled. Generally, you should flush a Navien Tankless Water Heater once a year. On the control board, the display does not turn on, there is no clicking from the ignitor, and no pump trys to run. So disabling and enabling the schedule does not work as a workaround to the hot button feature not showing up except for the fact that when enabled it will find that the reservoir temp is lower than it should be and begin to heat it, which then in turn will allow it to start to recirculate again (not time saving or water saving at all). Always On: It will repeat DHW recirculation. . Also alludes to the fact that recirculation control gets disabled too. Put the PCB box back in its original place and secure it using. Details: If you were to query the status of the cm-inventory via API or CLI, you could query all 3 manager/controller nodes and get a status of running. Navien NPE240A- Navilink,Navilink App, Recirculation settings And This is a complete guide on Navien Recirculation Settings. It is compliant with California Title 24. On the App, the Enable button appears and is highlighted and now controls the times I have programmed for on/off. This may eliminate the waiting for hot water depending on installation method. External with internal pump. Space-saving high-efficiency condensing boilers provide the ultimate heating and comfort experience. This is how to set up Navien Tankless water heater for recirculation in Residential applications. Adding a "Hot button" overrides schedulers (navilink or NR-20DU). You need a crossover valve installed under one of your faucets that is far away from the water heater (there are a few different styles but they all have four connections and get installed under a faucet). He has a good standing reputation for superior skills in heating, air conditioning, hot water tanks, and indoor air quality systems. That's it, there is no other response from the unit. Just want to confirm. What I am finding now is if you call at 8am Eastern time you get New Jersey. Press the M (menu) button on the front panel and choose the 1. Resources | Partners Login | Become an NSS |Certifications |Parts List | Technical Support | Careers |Global Network |Warranty, All contents copyright Navien Inc. | About Navien |Contact Us | Terms of Use |Privacy Policy |CCPA |Notices, Ultra-high efficiency condensing tankless water heaters, High efficiency non-condensing tankless water heaters, You accept the use of cookies as described in our, PeakFlowE Installation, Operation and Maintenance Manual, Manual De Sistema Ventilacion Comun Espanol (USA & Canada). Click here to see downloads for other products. the 2 mounting screws. Navien 240A Dip Switch Settings [Explained Everything] Every Navien Tankless Model, either 240A or 180A2, has two DIP switch locations. So I just got off with a "Senior" support specialist at Navien Customer support. Water heater without tanks, also called instant water heaters heat water immediately upon request. Lastly, press and hold down the OK button for 2 seconds to finalize the weekly schedule setting. Efficient, durable and high-performance products for any commercial application. Every A2 model On Navien Water Heaters, you can choose two pre-heating modes. How long do Navien tankless water heaters last? My pump seems to run every time I need hot water. We have a Navien NR-240A installed in new construction in 2012. Also, you can use the Navien Intelligent Preheating feature. Thanks. The NaviLink system attaches easily to any new or existing* Navien tankless water heater, combiboiler and boiler. Navien's NR-180A, NR-210A, NR-240A, NPE-180A, NPE-210A and NPE-240A models come with the ComfortFlow System. Thanks for your inquiry. For recirculation Navien is not clear as to the use of parameters. (if you want to schedule via App). Set the 2-way valve to INT. Residential Recirc setup with Navien NPE A for faster hot water 800-556-7556 or see HarryEklof.comFull Naivien information including dealer and Rep locators is available at www.navieninc.com Navien npe-240a recirculation settings Click here for more information about UPS. The Navilink app is "meh" at best and their documentation of the "smart" features is nonsensical. with a wire stripper befor e connecting it to the solenoid valve. So to speak "standard" recirc pumps are too small to get it the water heater to fire.If it is existing and it has worked in the past, then there may be something wrong with the circulator.Dave H. We have a Navien NR-240A installed in new construction in 2012. Looks fine, Y U NO WORK!? To exit the view information mode, just press the back button on the front panel. So, you must play with this setting and adjust it according to your water usage demand. Understanding Navien Recirculating Water Heater - Heating Help: The Wall Is there a link that I can find this parameter table at? and our Can someone help me reconnect? I love everything about the hardware. Completing the Install. "If you can't explain it simply, you don't understand it well enough". Is that correct? Resources | Partners Login | Become an NSS |Certifications |Parts List | Technical Support | Careers |Global Network |Warranty, All contents copyright Navien Inc. | About Navien |Contact Us | Terms of Use |Privacy Policy |CCPA |Notices, Ultra-high efficiency condensing tankless water heaters, High efficiency non-condensing tankless water heaters, You accept the use of cookies as described in our, makes it even easier to install and set up, 2" PVC up to 75 feet and 1/2" gas up to 24 feet, High efficiency up to 0.95 UEF and up to 15:1 TDR, Durable dual stainless steel heat exchangers, EZNav multi-line control with built-in intuitive software, Problem Solved: Gandy Installations Saves Customer Enough Space for a Refrigerator, Problem Solved: Steve Hosack of SC Hosack Plumbing Upgrades His Hair Stylist to Navien, Ways to save money on your water & electric bill. Internal with external pump. Workaround: Restart the cm-inventory service on each NSX-T mgmt/controller node using API or CLI. What I have found to keep it easy for understanding the schedule enable/disable on the appis to add the letter "d" at the end of the word being displayed. I agree with Spacecowboy-- The information I have refers to external recirculation with cold water line return, but I expect the settings would be the same with a dedicated return line. Replacing one NPE for two 90 gallon tanks ( one dead and one likely to die) was a cost savings even though the NPE and recirc is expensive. Efficient and earth-friendly products designed for any size home. They are: If you want to select or activate any of the two recirculation modes, you must do two things: You can enjoy several benefits if you activate the recirculation mode. Navien Tankless Water Heater Standby Mode, Rinnai Tankless Water Heater Not Getting Hot Enough [Solved], Zoeller Sump Pump Wont Turn On [7 Easy Solutions]. I have a Navien NPE-240A tankless heater, . Set the 2-way valve inside the water heater to "INT.". Either you select the Internal Recirculation Mode or the External Recirculation Mode, both these modes has three common recirculation loops: However, the External Recirculation mode has an additional recirculation loop called HotButton, which takes it apart from Recirculation mode. I got the same problem that I can not connect the Navilink to home wi-fi. Navien 30015307A Circulation Pump, NCB-E Models OEM PART $272.95 In Stock FREE SHIPPING Navien 30002583A High Limit Switch, OEM PART $18.85 In Stock FREE SHIPPING Navien HotButton Recirc Pump Control for NPE-A Series, PZZZ-00046 $115.45 In Stock FREE SHIPPING NAVIEN 30014189B NHB FLAME ROD ASSEMBLY, OEM Part $31.38 In Stock FREE SHIPPING Troubleshooting Navien NPE-240A Internal Recirculation Pump Since there is no stationary hot water vessel requiring periodic fire, water heaters without tank are generally among the most efficient options for both residential . PreReqs: RACADM ktpass Powershell 3.0 (2.0 probably works too, but I was using 3.0@ the time) Your root CA's cert This is so it AD Authentication can be setup Solution: It's not a complete solution, but hopefully it'll help you get started in your own endeavors.